Installing a Brocade | 2 |
CAUTION
For the
CAUTION
To ensure adequate bonding when attaching the ground lug, a minimum of 20 PSI of torque is required to be applied to the mounting hardware used to attach the ground lug.
FIGURE 104 Crimping the power supply wire in the lug
|
| 2 |
1 | 2 | 1 |
1 AWG power supply wire: | 2 Power lug | |
for 2400W power supply, use#4 AWG |
| |
for 3000W power supply, use #2 AWG |
|
4.Reconnect the power lugs to the power supply unit.
5.Connect the
NOTE
DC return must be isolated from the router ground
6.Replace the safety cover. Refer to Figure .
This equipment installation must meet NEC/CEC code requirements. Consult local authorities for regulations.
Removing Brocade MLXe-32 router DC power supplies
Follow these steps to remove a 2400W DC power supply in a Brocade
1.Ensure the main DC power breaker is OFF.
2.Use a #1 Phillips screwdriver to remove screw that secures the safety cover, as shown in Figure 102 on page 138. Remove the safety cover.
3.Use a #2 Phillips screwdriver to remove the screws securing the power lugs. Refer to Figure 103 on page 138.
4.Pull down on handle to remove power supply. Refer to Figure 100 on page 136.
Brocade MLX Series and Brocade NetIron XMR Hardware Installation Guide | 139 |
|
|