9 Hardware specifications for Brocade MLX routers
Hardware specifications for Brocade MLX routers
The following sections describe hardware specifications for Brocade MLX routers.
Power specifications
The following power supply frequency requirements apply to Brocade MLX
•AC Input Rating: 100 to 240V, 50/60 Hz, 16.0 A maximum per power supply
•AC Operating Voltage Range: 90 - 264V, 50/60 Hz
•Inrush current: 40A peak maximum at 25 degrees C (77 degrees F)
•DC Input Rating:
•DC Operating Range:
•Inrush current: 45A peak maximum at 25 degrees C (77 degrees F)
The following power supply frequency requirements apply to the Brocade
•AC Input Rating: 200
•AC Operating Voltage Range: 180 to 264V
•Inrush current: 30A peak maximum at 25 degrees C (77 degrees F)
•DC Input Rating:
•DC Operating Range:
•Inrush current: 45A peak maximum at 25 degrees C (77 degrees F)
Table 57 lists power consumption information for Brocade MLX routers with all base components installed, and with only the specified interface modules installed.
TABLE 57 | Brocade MLX router power consumption values |
|
|
|
|
|
| |||||
|
|
|
|
|
|
|
|
|
|
|
|
|
Model |
|
| @100 VAC |
|
|
| @200 VAC |
|
| |||
|
|
|
|
|
|
|
|
|
|
|
|
|
|
| Amps | Watts | BTU/hr |
| Amps | Watts |
| BTU/hr | Amps | Watts | BTU/hr |
|
|
|
|
|
|
|
|
|
|
|
| |
MLX routers with 8x10G interface modules only |
|
|
|
|
|
|
| |||||
|
|
|
|
|
|
|
|
|
|
|
| |
| 14 | 1389 | 4740 |
| 7 | 1389 |
| 4740 | 29 | 1389 | 4740 | |
|
|
|
|
|
|
|
|
|
|
|
|
|
| 28 | 2760 | 9419 |
| 14 | 2760 |
| 9419 | 57 | 2760 | 9419 | |
|
|
|
|
|
|
|
|
|
|
|
|
|
| 56 | 5591 | 19081 |
| 28 | 5591 |
| 19081 | 116 | 5591 | 19081 | |
|
|
|
|
|
|
|
|
|
|
|
|
|
| N/A | N/A | N/A |
| 57 | 11391 |
| 38876 | 237 | 11391 | 38876 | |
|
|
|
|
|
|
|
|
|
|
|
| |
MLX routers |
|
|
|
|
|
|
| |||||
|
|
|
|
|
|
|
|
|
|
|
| |
| 15 | 1445 | 4967 |
| 7 | 1455 |
| 4967 | 30 | 1435 | 4967 | |
|
|
|
|
|
|
|
|
|
|
|
|
|
| 29 | 2893 | 9873 |
| 14 | 2893 |
| 9873 | 60 | 2893 | 9873 | |
|
|
|
|
|
|
|
|
|
|
|
|
|
| 59 | 5857 | 19991 |
| 29 | 5857 |
| 19991 | 122 | 5857 | 19991 | |
|
|
|
|
|
|
|
|
|
|
|
|
|
| N/A | N/A | N/A |
| 60 | 11924 |
| 40696 | 248 | 11924 | 40696 | |
|
|
|
|
|
|
|
|
|
|
|
| |
MLX routers with legacy MLX interface modules only |
|
|
|
|
|
|
| |||||
|
|
|
|
|
|
|
|
|
|
|
| |
| 13 | 1313 | 4480 |
| 7 | 1313 |
| 4480 | 27 | 1313 | 4480 | |
|
|
|
|
|
|
|
|
|
|
|
|
|
| 26 | 2607 | 8899 |
| 13 | 2607 |
| 8899 | 54 | 2607 | 8899 | |
|
|
|
|
|
|
|
|
|
|
|
|
|
384 | Brocade MLX Series and Brocade NetIron XMR Hardware Installation Guide |
|
|