4 Attaching a management station

Removing Brocade NetIron XMR 3200 router DC power supplies

Follow these steps to remove a 2400W DC power supply in a Brocade NetIron XMR 3200 router:

1.Ensure the main DC power breaker is OFF.

2.Use a #1 Phillips screwdriver to remove the screws that secures the safety cover, as shown in Figure 207 on page 293. Remove the safety cover.

3.Use a #2 Phillips screwdriver to remove the screws securing the power lugs. Refer to Figure 208 on page 294.

4.Pull down on handle to remove power supply. Refer to Figure 205 on page 291.

Follow these steps to remove a 3000W DC power supply in a Brocade NetIron XMR 3200 router:

1.Ensure the main DC power breaker is OFF.

2.Use a #1 Phillips screwdriver to remove the screw that secures the safety cover, as shown in Figure 207 on page 293.

3.Pull down on the handle to remove the 3000W power supply. Refer to Figure 205 on page 291.

4.Use a #2 Phillips screwdriver to remove the screws securing the power lugs. Refer to Figure 208 on page 294.

Final steps

Follow these steps in the order listed to complete the installation:

“Attaching a management station”

“Activating the power source”

“Verifying proper operation”

Attaching a management station

You can manage your router in the following ways:

Connect a PC or terminal to the console port on the management module. From this port, you can assign an IP address to the management module and establish connections through Telnet or SSH.

Connect the router to your existing management network and manage the router and other network devices from a management station.

NOTE

The management network that you connect to through the 10/100 Ethernet port must be separate and isolated from the network over which user packets are switched and routed. For information about functionality on the management port, Refer to “Understanding management port functions” on page 317.