Brocade Communications Systems 53-1002373-02 Ver V5.0.0T163 Module 1 ni-mlx-20-port-1g-copper

Models: 53-1002373-02

1 452
Download 452 pages 21.42 Kb
Page 187
Image 187

Installing a Brocade MLX-8 router

3

An ESD wrist strap with a plug for connection to the ESD connector on the Brocade MLX-8 router.

DANGER

For safety reasons, the ESD wrist strap should contain a 1 megohm series resistor.

You can install a new interface module while the router is powered on and running.

The router ships with slot blanks installed in all empty module slots. The slot blanks help ensure proper airflow inside the router. You must remove the slot blank to install a module into a slot.

Although the slot blanks differ in size, the procedure for removing them is identical. You will need a flat-blade screwdriver to perform this task.

Follow these steps to remove a slot blank.

1.Loosen the screws on either end of the slot blank by hand or with a flat-blade screwdriver.

2.Pull the slot blank out of the router, and store it in a safe place for future use.

CAUTION

If you are hot-swapping a module, allow a minimum of two seconds after a module (or power supply or fan tray) has been removed before inserting a module in the same slot.

Follow these steps to install a module.

1.If you are installing a module in a slot which may have been configured for a different module type, remove the old configuration information by following these steps.

a.Use the show running-configcommand in config mode to determine the current configuration of the slot.

Brocade(config)# show running-config Current configuration:

!

ver V5.0.0T163

module 1 ni-mlx-20-port-1g-copper

!

This example shows that slot 1 has already been configured for a 20-port 1 Gbps copper interface module.

With the module designation from show running-configcommand output, use the no module <slot-number> <module-type> command to remove the configuration from slot 1.

Brocade(config)# no module 1 ni-mlx-20-port-1g-copper

This example removes the configuration from slot 1, leaving it ready for a new module.

2.Put on the ESD wrist strap and ground yourself by inserting the plug into the ESD connector on the front of the chassis.

3.Remove the module from the packaging.

4.Insert the module into the router slot, and slide the card along the card guide until the ejectors on either side of the module move close to the module front panel. Refer to Figure 120.

Brocade MLX Series and Brocade NetIron XMR Hardware Installation Guide

169

53-1002373-02

 

Page 187
Image 187
Brocade Communications Systems 53-1002373-02 manual Ver V5.0.0T163 Module 1 ni-mlx-20-port-1g-copper