Brocade Communications Systems 53-1002373-02 manual Fan modules 1 10, numbered as labeled

Models: 53-1002373-02

1 452
Download 452 pages 21.42 Kb
Page 78
Image 78

1 Router modules

FIGURE 41 Rear fan locations for Brocade MLX and Brocade NetIron XMR 32-slot routers

2

1

4

3

6

5

8

7

10

9

1 - 10 Fan modules 1 - 10, numbered as labeled

At startup, the fans operate at high speed. After a period of time, the management module changes the fan speed to low.

By default, the router polls the temperature sensor on each module every 60 seconds for a temperature reading. Depending on the results, the router will:

Leave the fan speed as is

Increase the fan speed

Decrease the fan speed

Shut down a module to prevent damage

If the temperature of a module exceeds specified high temperature thresholds, the system generates a Syslog message and SNMP trap. The system can also shut down the module if the temperature exceeds the highest threshold.

You can change default low and high temperature thresholds for modules and fan speeds. Refer to “Changing temperature thresholds for modules and fan speeds” on page 331.