Brocade Communications Systems 53-1002373-02 manual Maintenance and Field Replacement

Models: 53-1002373-02

1 452
Download 452 pages 21.42 Kb
Page 367
Image 367

 

Chapter

Maintenance and Field Replacement

8

 

 

 

 

This chapter describes how to perform any required maintenance on your device. It also describes how to install the following field-replaceable hardware:

Management modules

Compact flash cards in management modules

Interface modules

Switch fabric modules

Fiber optic transceivers

Fans

Power supplies

Fan deflectors

Air filters

Hardware maintenance schedule

DANGER

The procedures in this manual are for qualified service personnel.

Brocade routers require minimal maintenance for hardware components. It is recommended that you perform the following regular maintenance tasks:

Clean the fiber-optic connectors on a fiber-optic transceiver port and the connected fiber cable each time you disconnect the cable.

Replace the air filters quarterly.

You can also replace the following hardware components, as needed:

All modules (management, interface, and switch fabric).

Fiber-optic transceivers.

AC or DC power supplies.

Fan assemblies.

NOTE

The management, interface, and switch fabric modules are dedicated, which means that you must install them in Brocade routers only. If you install these modules in another Brocade device or you install a module intended for another Brocade device in a Brocade router, the device and modules will not function properly.

Brocade MLX Series and Brocade NetIron XMR Hardware Installation Guide