Brocade Communications Systems 53-1002373-02 manual Verifying proper operation

Models: 53-1002373-02

1 452
Download 452 pages 21.42 Kb
Page 251
Image 251

Verifying proper operation

3

Brocade# show module

Status

Ports Starting MAC

M1

Module

(upper): Brocade router Mgmt Module

Active

 

M2

(lower):

Active

 

F0: Brocade router Switch Fabric Module

 

S1:

 

 

S2:

 

 

S3:

 

 

S4: Brocade router 4-Port 10Gig Module

CARD_STATE_UP

4

000c.db80.0000

S5: Brocade router 4-Port 10Gig Module

CARD_STATE_UP

4

000c.db80.0000

S6: Brocade router 4-Port 10Gig Module

CARD_STATE_UP

4

000c.db80.0000

S7:

 

 

 

S8:

 

 

 

Syntax: show module

The Status column shows the module status. The management module status can be one of the following:

ACTIVE – The module is currently the active management module.

STANDBY – The module is currently the standby management module.

COMING UP – The module is coming up as the standby module. This status occurs if the standby management module becomes the active module during a switchover.

The switch fabric module status can be one of the following:

ACTIVE – The module is up and running.

BAD – The management module cannot initialize the switch fabric module.

An interface module status can be one of the following:

CARD_STATE_INIT – The system detects the module but the module is not up and running yet.

CARD_STATE_BOOT – The module is booting.

CARD_STATE_INTERACTIVE – The module is booting from interactive mode.

CARD_STATE_LP_SYNC – The software images are synchronized between the management module and interface module.

CARD_STATE_SYNC – The system is currently synchronizing the software image between the management module and interface module.

CARD_STATE_SOFTWARE_LOADED – The module has loaded the software image.

CARD_STATE_POWER_OFF – The module does not have power.

CARD_STATE_UP – The module is operating normally.

CARD_STATE_FAILED – The management module was unable to bring up an interface module. If you see this status, make certain that the interface module is installed properly. For more information, refer to “Installing Brocade MLX-4 modules” on page 158, “Installing Brocade MLX-8 modules” on page 167, “Installing Brocade MLX-16 router modules” on page 178, or “Installing Brocade MLX-32 router modules” on page 209.

CARD_DOWN_REASON_<explanation> – The module is in a nonfunctional state. This status appears with an explanation for why the module is down. For example, "CARD_DOWN_REASON_BOOT_FAILED.” If the explanation does not help you resolve the problem, contact technical support and provide the explanation included with this status.

Brocade MLX Series and Brocade NetIron XMR Hardware Installation Guide

233

53-1002373-02

 

Page 251
Image 251
Brocade Communications Systems 53-1002373-02 manual Verifying proper operation