The Status column shows the module status. The management module status can be one of the following:

ACTIVE – The module is currently the active management module.

STANDBY – The module is currently the standby management module.

COMING UP – The module is coming up as the standby module. This status occurs if the standby management module becomes the active module during a switchover.

The switch fabric module status can be one of the following:

ACTIVE – The module is up and running.

BAD – The management module cannot initialize the switch fabric module.

An interface module status can be one of the following:

CARD_STATE_INIT – The system detects the module but the module is not up and running yet.

CARD_STATE_BOOT – The module is booting.

CARD_STATE_INTERACTIVE – The module is booting from interactive mode.

CARD_STATE_LP_SYNC – The software images are synchronized between the management module and interface module.

CARD_STATE_SYNC – The system is currently synchronizing the software image between the management module and interface module.

CARD_STATE_SOFTWARE_LOADED – The module has loaded the software image.

CARD_STATE_POWER_OFF – The module does not have power.

CARD_STATE_UP – The module is operating normally.

CARD_STATE_FAILED – The management module was unable to bring up an interface module. If you see this status, make certain that the interface module is installed properly. For more information, refer to “Installing modules in a Brocade MLXe 16-slot router” on page 92, or “Installing modules in the Brocade MLXe-32 router” on page 122.

CARD_DOWN_REASON_<explanation> – The module is in a nonfunctional state. This status appears with an explanation for why the module is down. For example, "CARD_DOWN_REASON_BOOT_FAILED.” If the explanation does not help you resolve the problem, contact technical support and provide the explanation included with this status.