Router modules | 1 |
Power supply requirements for
Table 10 lists the power supply requirements for each type of router when installing
TABLE 10 Power supply requirements for
Router type | Number of | Power supply requirements |
|
| |
| Ethernet interface |
|
| modules installed |
|
|
|
|
three | one 1200W PSU | |
|
| for 1+1 redundancy, install two 1200W PSU |
|
|
|
| four | two 1200W PSU |
|
| for 2+2 redundancy, install four 1200W PSU |
|
|
|
four | one 1200W PSU | |
Brocade NetIron |
| for 1+1 redundancy, install two 1200W PSU |
XMR 4000 |
|
|
|
|
|
seven | two 1200W PSU | |
|
| for 2+2 redundancy, install four 1200W PSU |
|
|
|
| eight | three 1200W PSU |
|
| for 3+1 redundancy, install four 1200W PSU |
|
|
|
Brocade NetIron | eight | two 1200W PSU |
XMR 8000 |
| for 2+2 redundancy, install eight 1200W PSU |
|
|
|
All | sixteen | four 1200W PSU |
|
| for 4+4 redundancy, install eight 1200W PSU |
|
|
|
All | four 2400W PSU | |
|
| for 4+4 redundancy, install eight 2400W PSU |
|
|
|
Brocade MLX Series and Brocade NetIron XMR Hardware Installation Guide | 31 |
|