4 Installing a Brocade NetIron XMR 16000 router
CAUTION
For the
CAUTION
To ensure adequate bonding when attaching the ground lug, a minimum of 20 PSI of torque is required to be applied to the mounting hardware used to attach the ground lug.
FIGURE 190 Crimping the power supply wire in the lug
1
1AWG power supply wire
For 1200 W power supply, #8 AWG For 1800 W power supply, #6 AWG
5.Connect the -48V cable to the negative terminal and the 0V cable to the positive terminal as marked on the power supply.
NOTE
DC return must be isolated from the device ground (DC-I) when connecting to the power supply.
6.Replace the transparent plastic cover and screws.
This equipment installation must meet NEC/CEC code requirements. Consult local authorities for regulations
Final steps
Follow these steps to complete the installation:
•“Attaching a management station”
•“Activating the power source”
•“Verifying proper operation”
272 | Brocade MLX Series and NetIron XMR Hardware Installation Guide |
|
|