9 Hardware specifications for Brocade NetIron XMR routers
•Inrush current: 45A peak maximum at 25 degrees C (77 degrees F) Table 62 lists the maximum power calculations for Brocade NetIron XMR routers.
TABLE 62 | Brocade NetIron XMR router power consumption values |
|
|
|
| |||||
|
|
|
|
|
|
|
|
|
|
|
Model |
|
| @100 VAC |
|
| @200 VAC |
|
| @ 48 VDC |
|
|
|
|
|
|
|
|
|
|
|
|
|
| Amps | Watts | BTU/hr | Amps | Watts | BTU/hr | Amps | Watts | BTU/hr |
|
|
|
|
|
|
|
|
|
| |
Brocade NetIron XMR 4000 | 14 | 1384 | 4724 | 7 | 1384 | 4724 | 29 | 1384 | 4724 | |
|
|
|
|
|
|
|
|
|
| |
Brocade NetIron XMR 8000 | 28 | 2750 | 9386 | 14 | 2750 | 9386 | 57 | 2740 | 9386 | |
|
|
|
|
|
|
|
|
|
| |
Brocade NetIron XMR 16000 | 56 | 5572 | 19017 | 28 | 5572 | 19017 | 116 | 5572 | 19017 | |
|
|
|
|
|
|
|
|
|
| |
Brocade NetIron XMR 32000 | N/A | N/A | N/A | 57 | 11353 | 38476 | 237 | 11353 | 38476 | |
|
|
|
|
|
|
|
|
|
|
|
Table 63 lists the maximum power consumption, in watts, for individual components within a Brocade NetIron XMR router.
TABLE 63 Maximum power consumption for Brocade NetIron XMR router components
Component | Maximum power |
| consumption, in watts |
|
|
Management modules |
|
|
|
MR management module (Brocade NetIron XMR 4000, 8000 and 16000) | 30W |
|
|
MR management module (Brocade NetIron XMR 32000) | 35W |
|
|
MR2 management module | 40W |
16000) |
|
|
|
MR2 management module | 45W |
|
|
Switch fabric modules |
|
|
|
19W | |
|
|
53W | |
|
|
60W | |
|
|
|
|
|
|
| 19W |
|
|
53W | |
|
|
60W | |
|
|
POS interface modules |
|
|
|
125W | |
|
|
220W | |
|
|
115W | |
|
|
132W | |
|
|
230W | |
|
|
Interface modules |
|
|
|
485W | |
|
|
150W | |
|
|
245W |