Brocade Communications Systems 53-1002373-02 Displaying device status and temperature readings

Models: 53-1002373-02

1 452
Download 452 pages 21.42 Kb
Page 342
Image 342

7 Managing the device

If an I2C failure has not occurred, there will be no I2C messages in the static log, dynamic log, or SNMP log server. The following example shows output from the show logging command when there is no I2C failure.

Brocade# show logging

 

Syslog

logging: enabled (0 messages dropped, 0 flushes, 1 overruns)

Buffer

logging: level ACDMEINW, 50 messages logged

level code: A=alert C=critical D=debugging

M=emergency E=error

I=informational N=notification W=warning

 

Static

Log Buffer:

middle, Not Installed (FAILED)

Apr 16

18:21:25:A:System: Power Supply 2 ,

Apr 16

18:21:25:A:System: Power Supply 3 ,

top, Not Installed (FAILED)

Dynamic Log Buffer (50 lines):

MED (75%)

Mar 28

12:36:47:A:System: Set fan speed to

Mar 25

21:40:47:A:System: Set fan speed to

MED-HI (90%)

Mar 25

16:30:47:A:System: Set fan speed to

MED (75%)

Mar 23

23:12:07:A:System: Set fan speed to

MED-HI (90%)

If the system detects a major I2C failure, the system prevents the management module from accessing devices through the l2C serial bus. The output from the show chassis command and the show temperature command reflect this action, as shown in these examples.

Brocade# show chassis

*** Note: ***

*** Global I2C Error Indicator is set (severity: Major). ***

*** All I2C access are skipped. ***

*** Brocade MLX-4 device ***

---POWERS ---

Slot Power-On Priority and Power Usage:

Slot2 pri=1 module type=NI-MLX-1Gx20-GC 20-port 10/100/1000 Copper Module power usage=146W Slot4 pri=1 module type=NI-X-OC48x4 4-port OC48/12 STM16/STM4 Module power usage=132W

---FANS ---

---TEMPERATURE READINGS ---

LP2 Sensor1: 34.500C

LP2 Sensor2: 44.125C

The following output is from the show temperature command with the GIEI set to major severity.

Brocade# show temperature

*** Note: ***

*** Global I2C Error Indicator is set (severity: Major). ***

*** All I2C access are skipped. ***

SLOT #: CARD TYPE: SENSOR # TEMPERATURE (C): 2 LP 1 34.0C

2 LP 2 44.250C

4 LP 1 36.0C

4 LP 2 45 750C

Displaying device status and temperature readings

You can display the following information about the router:

Power-on priority of the device slots

Status of the fans

Temperature readings of the management, switch fabric, interface, and fan control modules and the interval at which the system reads the temperature of these modules

MAC address of the device