Brocade Communications Systems 53-1002373-02 manual Module Slot number

Models: 53-1002373-02

1 452
Download 452 pages 21.42 Kb
Page 274
Image 274

4 Installing a Brocade NetIron XMR 8000 router

or Type 4 ports as described in GR-1089-CORE, Issue 5) and require isolation from the exposed OSP cabling. The addition of Primary Protectors is not sufficient protection in order to connect these interfaces metallically to OSP wiring.

NOTE

Brocade NetIron XMR modules are dedicated, which means that you must install them in a Brocade NetIron XMR router only. For example, if you install the Brocade NetIron XMR module in another Brocade device or install a module intended for another Brocade device in the Brocade NetIron XMR router, the router and module will not function properly.

Although management modules are designed to be hot-swappable, you must upgrade the software on all interface modules and management modules to the appropriate software release before installing them. For more information on the appropriate software release, refer to the Hardware Installation Notes that shipped with the management module.

For information about how to disable and re-enable power to interface modules, see “Disabling and re-enabling power to interface modules” on page 321

Table 41 provides the slot numbers where you can install modules. Identification marks appear a the base of each slot.

TABLE 41 Brocade NetIron XMR 8000 module installation

Module

Slot number

 

 

Management modules

Active module – M1 (left).

 

Redundant module – M2 (right).

 

 

1 – 8

Interface modules

 

 

SF1 – SF3

Switch fabric modules

 

 

The Brocade NetIron XMR 8000 router ships with slot blanks installed in all empty module slots. The slot blanks cover empty slots, ensuring proper airflow within the router. Before you install a module in a slot, you must remove the slot blank.

CAUTION

If you do not install a module in a slot, you must keep the slot blank in place. If you operate the router with an uncovered slot, the system may overheat. Tighten the screws that secure the slot blanks so that they remain in place when removing adjacent panels or modules.

Although slot blanks differ in size, the procedure for removing them is the same. You will need a flat-blade screwdriver to perform this task.

Follow the steps to remove a slot blank.

1.Loosen the screws on either end of the slot blank by hand or with a flat blade screwdriver.

2.Pull the slot blank out of the router, and store it in a safe place for future use.

NOTE

If you are installing a redundant management module, refer to Brocade MLX Series and Brocade NetIron Family Configuration Guide, Chapter 8: Using a Redundant Management Module, for information about how the redundant module works, optional software configurations, and how to manage redundancy.