1 Router modules

NI-MLX-1Gx48-T-A interface module

Figure 25 shows the front panel of the NI-MLX-1Gx48-T-A interface module.

FIGURE 25 NI-MLX-1Gx48-T-A module front panel

A

The front panel includes the following features:

A power LED located below the part number

Eight mini-RJ21 connectors, each supporting six 10/100/1000 Mbps Ethernet ports

The eight mini-RJ21 connectors support six 1 Gbps Ethernet ports each. You can connect a patch panel with a mini-RJ21 connector to a mini-RJ21 connector on the interface module. The patch panel provides RJ45 connectors. You can also use a cable with a mini-RJ21 connector on one end that connects to the mini-RJ21 connector on the interface module. The other end of the cable splits into six cables with RJ45 connectors on each cable.

The NI-MLX-1Gx48-T-A module ships with two cable cinches. Each cable cinch consists of a plastic part and a velcro strap. For instructions on using the cable cinches, see Chapter 5, “Using Brocade Structured Cabling Components”.

Cables and patch panels that support this module are available through any Tyco International distribution partner. Information about these products is available at the following URL.

https://www.ampnetconnect.com/foundrynetworks

NOTE

Before you install NI-MLX-1Gx48-T-A modules, you must first upgrade the software on all interface modules and management modules to the appropriate software release. For more information refer to the Hardware Installation Notes that shipped with the modules.