Brocade Communications Systems 53-1002373-02 manual

Models: 53-1002373-02

1 452
Download 452 pages 21.42 Kb
Page 341
Image 341

Managing the device

7

MUX index number:

-0-1 - there are total of 2 MUX indexes in Brocade NetIron XMR 32000 and Brocade MLX-32 devices.

-The MUX index is always zero in 4-, 8-, and 16-slot Brocade NetIron XMR or Brocade MLX devices

MUX tap number:

-0-7 - there are total of 8 MUX taps connected to a MUX device.

-15 - MUX tap is non applicable

Device ID

Device address

Description of the load

If the GIEI severity changes from the time the GIEI is set to major, the first Syslog message in the static section of the log is updated to reflect this change. A copy of this updated message is generated in the dynamic section of the log and a copy is sent to SNMP log server.

When an I2C failure is first detected, a second Syslog message is generated containing information about the last successful I2C access before the GIEI error flag was set. The last successful access information remains unchanged until the GIEI is cleared. A copy of the second Syslog message is also sent to the SNMP log server.

The second Syslog message is always displayed as an informational Syslog. The following example shows an informational Syslog message:

Brocade# show logging

Syslog logging: enabled (0 messages dropped, 0 flushes, 1 overruns)

Buffer logging: level ACDMEINW, 50 messages logged

level code: A=alert C=critical D=debugging M=emergency E=error I=informational N=notification W=warning

Static Log Buffer:

Apr 16 18:21:25:A:System: Power Supply 2 , middle, Not Installed (FAILED)

Apr 16 18:21:25:A:System: Power Supply 3 , top, Not Installed (FAILED)

Apr 16 18:22:12:I:System: i2c recovered (GIEI = clear), Severity Minor, Mux index 0, Mux tap 4, ID 0x4, Addr 0x5, (FANTRAY4)

Dynamic Log Buffer (50 lines):

Apr 16 18:22:12:I:System: i2c recovered (GIEI = clear), Severity Minor, Mux index 0, Mux tap 4, ID 0x4, Addr 0x5, (FANTRAY4)

Apr 16 18:21:27:I:System: bad i2c access (GIEI = set), Severity Minor, Mux index 0, Mux tap 4, ID 0x4, Addr 0x5, (FANTRAY4)

Apr 16 18:21:25:A:System: bad i2c access (GIEI = set), Severity Major, Mux index 0, Mux tap 4, ID 0x4, Addr 0x5, (FANTRAY4)

Apr 16 18:21:24:I:System: last good i2c access, Mux index 0, Mux tap 1, ID 0x9, Addr 0x1, (SNM1TEMP)

When the GIEI flag is cleared, the first Syslog message in the static section of the log is updated to show that the GIEI is set to clear. The second Syslog message in the static section is removed. A copy of the updated first Syslog message is also generated in the dynamic section of the log and in SNMP log server.

When a problematic device is removed from the system, the GIEI is cleared and all Syslog messages are updated to show that the GIEI is set to clear.

Brocade MLX Series and Brocade NetIron XMR Hardware Installation Guide

323

53-1002373-02

 

Page 341