Brocade Communications Systems 53-1002373-02 manual CFP optics

Models: 53-1002373-02

1 452
Download 452 pages 21.42 Kb
Page 44
Image 44

1 Router modules

CFP optics

The 100 GbE interface module is 802.3ba compliant, supports CFP-based optics, and is backwards-compatible with existing Brocade MLX and Brocade NetIron XMR interface modules. This interface module requires high-speed fabric modules. 100GbE interface modules will boot in turbo mode if all modules in the chassis are Gen-2 modules.

You must insert CFP-compliant fiber-optic transceivers in each port you intend to use. CFP-compliant transceivers provide an optical or physical medium-dependent (PMD) interface for single- or multi-mode fiber that can be used with either the LAN physical layer (PHY) or WAN physical layer (WAN PHY).

For a list of supported 100xGbE CFP-compliant fiber-optic transceivers that are available from Brocade, refer to the latest version of the Brocade Optics Family Data Sheet, available online in the following location:

http://www.brocade.com/downloads/documents/data_sheets/product_data_sheets/Optics_DS.p df

For more information about fiber-optic transceivers and associated cabling, refer to “Installing a fiber-optic transceiver” on page 318.

Power supply requirements for 100xGbE modules

Table 6 lists the power supply requirements for each type of router when installing 100xGbE modules.

TABLE 6 Power supply requirements for 100xGbE modules

Router type

Number of 100xGbE

Power supply requirements (minimum required-redundancy requirements)

 

modules installed

 

 

 

 

MLXe-4

one

one 1200W PSU

 

 

for 1+1 redundancy, install two 1200W PSU

 

 

 

 

 

one 1800W PSU

 

 

for 1+1 redundancy, install two 1800W PSU

 

 

 

 

two

two 1200W PSU

 

 

for 2+1 redundancy, install three 1200W PSU

 

 

 

 

 

one 1800W PSU

 

 

for 1+1 redundancy, install two 1800W PSU

 

 

 

MLX-4 and

two (1x100GE)

one 1200W PSU

Brocade NetIron

 

for 1+1 redundancy, install two 1200W PSU

XMR 4000

 

 

 

 

 

MLXe-8

two

two 1200W PSU

 

 

for 1+1 redundancy, install four 1200W PSU

 

 

 

 

 

one 1800W PSU

 

 

for 1+1 redundancy, install two 1800W PSU

 

 

 

 

three or four

three 1200W PSU

 

 

for 3+1 redundancy, install four 1200W PSU

 

 

 

 

 

two 1800W PSU

 

 

for 2+2 redundancy, install four 1800Q PSU

 

 

 

Brocade NetIron

four (1x100GE)

two 1200W PSU

XMR 8000

 

for 2+2 redundancy, install four 1200W

26

Brocade MLX Series and Brocade NetIron XMR Hardware Installation Guide

 

53-1002373-02

Page 44
Image 44
Brocade Communications Systems 53-1002373-02 manual CFP optics, Power supply requirements for 100xGbE modules