Brocade Communications Systems 53-1002373-02 manual Clearing power supply failure timestamps

Models: 53-1002373-02

1 452
Download 452 pages 21.42 Kb
Page 373
Image 373

Replacing a power supply

8

NOTE

A threshold value of 0 will not automatically shutdown a power supply due to failures.

For Syslog messages, please refer to Appendix A, Using Syslog in the Brocade MLX Series and Brocade NetIron Family Configuration Guide.

Clearing power supply failure timestamps

Use the power-supply monitoring clear command to clear all collected failure timestamps for a given power supply, or for all available power supplies.

To clear all collected failure timestamps for a power supply, enter the following command.

Brocade(config)# power-supply monitoring clear 1

This will clear all collected failure timestamps for the Power Supply # 1 Are you sure? (enter 'y' or 'n'): y

To clear all collected failure timestamps for all available power supplies, enter the following command.

Brocade(config)# power-supply monitoring clear all

This will clear all collected failure timestamps for all available Power Supplies Are you sure? (enter 'y' or 'n'): y

You are asked to verify this command by entering “yes” or “no. Syntax: power-supply monitoring clear <decimal all>]

By default, no power-supply monitoring is configured.

The <decimal> variable specifies a power supply number, The all keyword clears all available power supplies.

Displaying power supply monitoring timestamps

To display timestamps for failures on any power supply, enter the following command.

Brocade#

show power-supply-monitoring

PS-6

PS-7

 

PS-8

PS-1

PS-2

PS-3

PS-4

PS-5

 

1

) 0

0

0

0

0

 

0

0

0

2

) 0

0

0

0

0

 

0

0

0

3

) 0

0

0

0

0

 

0

0

0

4

) 0

0

0

0

0

 

0

0

0

5

) 0

0

0

0

0

 

0

0

0

6

) 0

0

0

0

0

 

0

0

0

7

) 0

0

0

0

0

 

0

0

0

8

) 0

0

0

0

0

 

0

0

0

9

) 0

0

0

0

0

 

0

0

0

The show power-supply-monitoringcommand displays the last 32 recorded failure timestamps for a power supply. The current configured power supply monitoring threshold value is also displayed at the end of the output.

Syntax: show power-supply-monitoring

Brocade MLX Series and Brocade NetIron XMR Hardware Installation Guide

355

53-1002373-02

 

Page 373
Image 373
Brocade Communications Systems 53-1002373-02 manual Clearing power supply failure timestamps