Brocade Communications Systems 53-1002373-02 manual Verifying proper operation, Observing the LEDs

Models: 53-1002373-02

1 452
Download 452 pages 21.42 Kb
Page 160
Image 160

2 Verifying proper operation

NOTE

Because the router is designed to provide uninterrupted service even when you insert or remove management modules and interface modules, there is no on/off power switch. To turn the system off, simply unplug the power cords.

NOTE

Wall outlets should be installed near the equipment and should be easily accessible.

4.Verify that the router has initialized successfully. Refer to “Verifying proper operation” on page 142.

Verifying proper operation

To verify that your router is operating properly, observe the LEDs, or display the status of the modules using the CLI.

Observing the LEDs

When power is supplied to the router, you can observe the LEDs to verify that the router initialized successfully. Table 33 describes the LEDs, the desired state of each LED, possible abnormal states of each LED, and what to do if an LED indicates an abnormal state.

TABLE 33

Router LED states and actions

 

 

 

 

 

 

 

 

LED label

 

Desired state

Meaning

Abnormal

Meaning or action

 

 

 

 

state

 

 

 

 

 

Management module

 

 

 

 

 

 

 

 

 

Active

 

The Active LED on

The module is

Off

Neither of the management modules is managing the switch

 

 

one of the installed

functioning as the

 

fabric and interface modules. A problem may have occurred

 

 

management

active management

 

during initialization. Check your attached PC or terminal for

 

 

modules should be

module.

 

possible error messages.

 

 

on.

 

 

 

 

 

 

 

 

 

Pwr

 

On

The module is

Off

The module is not receiving power. Check the following:

 

 

 

receiving power.

 

Make certain that the module is installed properly. For more

 

 

 

 

 

information, refer to the module installation section in this

 

 

 

 

 

chapter that applies to your router model.

 

 

 

 

 

If you are using AC power supplies, refer to the AC power

 

 

 

 

 

supply LED information in this table for more information.

 

 

 

 

 

10/100/1000

On (green)

A link is established

Off

A link is not established with the remote port. Check the

Ethernet Port

 

 

with the remote

 

following:

 

 

 

port.

 

Verify that the connection to the other router has been

properly made. Also, make certain that the other router is powered on and operating correctly.

Try using a different cable.

142

Brocade MLX Series and NetIron XMR Hardware Installation Guide

 

53-1002373-02

Page 160
Image 160
Brocade Communications Systems 53-1002373-02 manual Verifying proper operation, Observing the LEDs