Installing a Brocade | 2 |
CAUTION
For the
CAUTION
To ensure adequate bonding when attaching the ground lug, a minimum of 20 PSI of torque is required to be applied to the mounting hardware used to attach the ground lug.
FIGURE 51 Crimping the power supply wire in the lug
1
1AWG power supply wire:
#8 AWG power supply wire for 1200W power supplies #6 AWG power supply wire for 1800W power supplies
4.Connect the
NOTE
DC return must be isolated from the router ground
5.Replace the transparent cover over the lugs.
This equipment installation must meet NEC/CEC code requirements. Consult local authorities for regulations.
Final steps
Complete these steps in the order listed:
•“Attaching a management station”
•“Activating the power source”
•“Verifying proper operation”