BSR 2000 Command Reference Guide

Release 1.0

 

 

show packet-cable gate

The show packet-cable gate command display the gate ID in hexidecimal notation, CM MAC address, CPE (subscriber) IP address, cable slot number, upstream and downstream Service Flow Identifier (SFID) number, status and committed time gate summary information

The following provides typical screen output from the show packet-cable gate command:

DQoS Gates: 2

--------------------------------------------------------------------------------

GateID

Modem

Subscriber

CM

SFID

Pri

Status

Committed

(0x)

MAC Address

IP Address

TS Up

Dn

 

Time

--------------------------------------------------------------------------------

00000D3C 0011.8065.f57a

150.31.55.101

0

57

58 Low

Committed 00:21:58

00000E86 0011.8065.f580

150.31.55.102

0

55

56 Low

Committed 00:21:58

The following provides the show packet-cable gate command output field

descriptions:

 

 

 

 

 

 

GateID (0x)

 

display the gate Identifier in

 

 

 

hexadecimal notation

 

Modem MAC Address

cable modem (CM) MAC address

Subscriber IP Address

Client IP address

 

 

CMTS

 

This number is always 0 for the BSR

 

 

2000.

 

 

 

SFID

 

display the upstream (Up) SFID

 

 

number, and the downstream (Dn)

 

 

Service Flow Identifier (SFID)

 

 

number.

 

 

 

Pri

 

gate priority, which is either high or

 

 

low.

 

 

 

Status

 

gate status

 

 

Committed Time

time at which the gate was

 

 

 

committed

 

 

16-50

MGBI

526363-001-00 Rev. B

Page 1026
Image 1026
Motorola BSR 2000 manual Show packet-cable gate, Sfid