cable upstream invited-range-interval

The cable upstream invited-range-intervalcommand is used to define the amount of time in milliseconds allowed by the CMTS between ranging requests transmitted by the cable modem (CM). The no cable upstream invited-range-intervalcommand returns to the default value.

Group Access

MSO

Command Mode

Interface Configuration (cable interface only)

Command Line Usage

cable upstream <NUM> invited-range-interval <0-30000>no cable upstream <NUM> invited-range-interval <0-30000>

Command Syntax

NUM

the upstream port number

0-30000

the time in milliseconds allowed by the

 

CMTS between ranging requests transmitted

 

by the cable modem

Command Default

10000 milliseconds