BSR 2000 Command Reference Guide

Release 1.0

 

 

cable downstream frequency

The cable downstream frequency command is used to set the fixed center downstream frequency for RF output. The no cable downstream command returns the fixed center downstream frequency of RF output to the default..

Note: The Japan DOCSIS Standard must be specified with the cable cmts type command before a downstream frequency can be selected for any Japan DOCSIS Standard CMTS module.

Note: The digital carrier frequency cannot be the same as the video carrier frequency.

Group Access

MSO

Command Mode

Interface Configuration (cable interface only)

Command Line Usage

North American DOCSIS Standard

cable downstream [<0-0>]frequency <91000000-857000000>no cable downstream [<0-0>]frequency <91000000-857000000>

Euro-DOCSIS Standard

cable downstream [<0-0>]frequency <112000000-858000000>no cable downstream [<0-0>]frequency <112000000-858000000>

Japan DOCSIS (J-DOCSIS) Standard

cable downstream [<0-0>]frequency <91000000-860000000>no cable downstream [<0-0>]frequency <91000000-860000000>

11-10

MGBI

526363-001-00 Rev. B

Page 556
Image 556
Motorola BSR 2000 manual Cable downstream frequency, Japan Docsis J-DOCSIS Standard