CMTS Commands

 

 

cable upstream snr-offset

The cable upstream snr-offsetcommand configures the display an SNR value with an offset. The offset can be configured for each upstream port up to a value of 100 (10 dB) in 10 (1 dB) increments. The offset value will be added to the SNR value when it is displayed with the show controllers and show interfaces cable upstream signal-qualityCLI commands and through SNMP. The offset value will not be added to the actual SNR reading that is used by critical tasks such as Spectrum Management.

Group Access

MSO

Command Mode

Interface Configuration (cable interface only)

Command Line Usage

cable upstream <NUM> snr-offset {10 20 30 40 50 60 70 80 90 100} no cable upstream <NUM> snr-offset {10 20 30 40 50 60 70 80 90 100}

526363-001-00 Rev. B

MGBI

11-103

Page 649
Image 649
Motorola BSR 2000 manual Cable upstream snr-offset