Release 1.0

CMTS Commands

 

 

cable upstream map-interval

The cable upstream map-intervalcommand is used to determine the time interval in microseconds for bandwidth maps messages (MAP) to be used by the CM to allocate upstream time slots. The no cable upstream map-intervalcommand resets the upstream interval to the default.

Group Access

MSO

Command Mode

Interface Configuration (cable interface only)

Command Line Usage

cable upstream <NUM> map-interval <2000-16000>no cable upstream <NUM> map-interval <2000-16000>

Command Syntax

NUM

Upstream port number

2000-16000

Interval value in microseconds.

Command Default

4000 microseconds