Release 1.0

CMTS Commands

 

 

cable upstream iuc11-grant-size

The cable upstream iuc11-grant-sizecommand specifies the size of the Interval Usage Code (IUC) 11 Advanced Unsolicited Grant burst descriptor when configuring a DOCSIS 2.0 upstream logical channel.

Note: If a modulation profile for an upstream channel does not support IUC 11, the configuration of the IUC 11 byte size will be not be allowed. If a modulation profile for an upstream channel is changed and the new modulation profile does not support IUC 11, the IUC 11 byte size muset be reset to "0".

Group Access

MSO

Command Mode

Interface Configuration (cable interface only)

Command Line Usage

cable upstream <X/Y> iuc11-grant-size [<0-1024>]no cable upstream <X/Y> iuc11-grant-size [<0-1024>]

Command Syntax

X/Y

the upstream port and logical channel number

 

(0-3)

0-1024

the grant size in bytes

Command Default

0 bytes