Release 1.0 | CMTS Commands |
|
|
cable downstream description
The cable downstream description command is used to specify descriptive information for a downstream port on the BSR. This information is limited to 80 characters and single word descriptions are not allowed. Use the characters: _ or - to separate words. For example, if a downstream port served a certain section of a city, the MSO could assign the following description:
MOT(config-if)#cable downstream 0 description charlestown_1D
Note: The entered description can be seen in the running configuration, and in the command output of show commands such as the show ip interface and show
Command Mode
Interface Configuration (cable interface only)
Command Line Usage
cable downstream <0-1> description <LINE>
Command Syntax
is the downstream port number. | |
LINE | is the text that describes the interface. |
MGBI |