BSR 2000 Command Reference Guide

Release 1.0

 

 

cable downstream carrier-only

The downstream carrier-only function is disabled by default and is used for testing purposes only to control downstream output. The cable downstream carrier-onlycommand is used optionally as a test function to enable the modulation to the RF carrier of the downstream output. The no cable downstream carrier-onlycommand disables the modulation to the RF carrier of the downstream output.

Note: If the cable downstream carrier-only command is used, set the rfModulation to 1.

If the no cable downstream carrier-only command is used, set the rfModulation to 0.

Group Access

MSO

Command Mode

Interface Configuration (cable interface only)

Command Line Usage

cable downstream [<0-0>]carrier-only no cable downstream [<0-0>]carrier-only

Command Syntax

0-0

Downstream port number.

Command Default

Modulation to the RF carrier is disabled.

11-8

MGBI

526363-001-00 Rev. B

Page 554
Image 554
Motorola BSR 2000 manual Cable downstream carrier-only