Release 1.0

CMTS Commands

 

 

cable upstream range-backoff

Use the cable upstream range-backoffcommand to set the start and end upstream range-backoff values for a CM or re-establish a CM if a power outage occurs. Use the no cable upstream range-backoffcommand return the ranging back-off default value. If you choose automatic, the system sets the upstream data-backoff start and end values.

Group Access

MSO

Command Mode

Interface Configuration (cable interface only)

Command Line Usage

cable upstream <NUM> range-backoff {<0-15> <0-15> automatic} no cable upstream <NUM> range-backoff {<0-15> <0-15> automatic}

Command Syntax

NUM

Upstream port number

0-15

Start of range backoff

0-15

End of range backoff

automatic

Automatic range backoff.

Command Default

start 0, end 4

526363-001-00 Rev. B

MGBI

11-99

Page 645
Image 645
Motorola BSR 2000 manual Cable upstream range-backoff, Automatic