Release 1.0

CMTS Commands

 

 

fft start

The fft start command initiates the power level measurement using the FFT algorithm via the RF Sentry.

Note: The sample, mode, and window arguments are optional with the fft start command but can be used to override the current FFT processor configuration specified with the fft setup command and initiate power level measurement with a new FFT processor configuration.

Group Access

MSO

Command Mode

Privileged EXEC

Command Line Usage

fft start <Slot/Port> [sample {<256-2048>}] [mode {Tap-in}] [window {rectangular hamming hanning blackman blackman-harris}]

Command Syntax

Slot/Port

Slot is always 0 for the BSR 2000. Port is a

 

valid upstream port number.

sample 256-2048

number of samples of the power level

 

measurement

mode Tap-in

RF Sentry operational mode

window

window coefficient to shape the output of the

 

power level measurement (rectangular,

 

hamming, hanning, blackman, or

 

blackman-harris)

526363-001-00 Rev. B