Release 1.0 | CMTS Commands |
|
|
fft start
The fft start command initiates the power level measurement using the FFT algorithm via the RF Sentry.
Note: The sample, mode, and window arguments are optional with the fft start command but can be used to override the current FFT processor configuration specified with the fft setup command and initiate power level measurement with a new FFT processor configuration.
Group Access
MSO
Command Mode
Privileged EXEC
Command Line Usage
fft start <Slot/Port> [sample
Command Syntax
Slot/Port | Slot is always 0 for the BSR 2000. Port is a |
| valid upstream port number. |
sample | number of samples of the power level |
| measurement |
mode | RF Sentry operational mode |
window | window coefficient to shape the output of the |
| power level measurement (rectangular, |
| hamming, hanning, blackman, or |
|
MGBI |