BSR 2000 Command Reference Guide

Release 1.0

 

 

cable downstream interleave-depth

The cable operator can protect the downstream path from excess noise or decrease latency on the downstream path by setting the interleave depth. A higher interleave depth provides more protection from noise on the HFC network, but increases downstream latency. A lower interleave depth decreases downstream latency, but provides less protection from noise on the HFC network.

The cable downstream interleave-depth command sets the downstream port interleave depth criteria.

Note: A higher interleave depth provides more protection from bursts of noise on the HFC network; however, it increases downstream latency.

Group Access

MSO

Command Mode

Interface Configuration (cable interface only)

Command Line Usage

cable downstream [<0-0>]interleave-depth {8 16 32 64 128} no cable downstream [<0-0>]interleave-depth {8 16 32 64 128}

Command Syntax

0-0

Downstream port number.

Review Table 11-1to determine the appropriate interleave-depth.

Table 11-1 Interleave Depth Criteria

Depth

# of Taps

Increments

 

 

 

8

8

16

 

 

 

12

12

17

 

 

 

16

16

8

 

 

 

11-12