BSR 2000 Command Reference Guide | Release 1.0 |
|
|
snr loop
The snr loop command allows an operator to perform SNR measurements for a specified number of times on one particular frequency.
Group Access
MSO
Command Mode
Privileged EXEC
Command Line Usage
snr loop {<NUM>} {<NUM>}{<NUM>}{<NUM>}{<frequency>} {1600000 200000 3200000 400000 6400000 800000} [<mac> equalization {off on}
Command Syntax
NUM | This number is always 0 for the BSR 2000. |
NUM | valid upstream port number |
NUM | the number SNR measurement repetitions |
| |
NUM | a ranging pattern number used to look up a |
| certain pattern to be used for SNR |
| measurement |
frequency | the particular frequency to perform SNR |
| measurements on |
1600000 | channel width 1600 kHz |
200000 | channel width 200 kHz |
3200000 | channel width 3200 kHz |
400000 | channel width 400 kHz |
6400000 | channel width 6400 kHz |
800000 | channel width 800 kHz |
MGBI |