451
EES4710BD 10 Slots L2/L3/L4 Chassis Switch
Click “OSPF area configuration” to enter the configuration page for port. Equivalent to CLI
command 18.4.2.2.9
z Vlan port: port list
z Area ID: area number
z Reset: resets each column value to default in this page and this action will not change settings
z Apply: valid each column value. This action will change settings.
z Default: resets to default setting. This action will change settings.
Example: to configure port vlan 1 to area 1, port select vlan 1, key-in area number 1 and click Apply
button.
Click “OSPF Tx-parameter configuration” to open the configuration table. Includes:
z OSPF authentication parameter configuration
z Passive interface configuration: Configures OSPF port as receiving packets only
z Sending packet cost configuration: configures the cost and timer parameter for the port
sending data packets.
Click “OSPF authentication parameter configuration” to enter the configuration page. Equivalent to
CLI command 18.4.2.2.6
z Vlan port: port list
z Authentication mode: simple and MD5.
z Authentication key
z KeyID: the authentication word in MD5 authentication mode
z Reset: resets each column value to default in this page and this action will not change settings
z Apply: valid each column value and this action will change settings
Example: To configure MD5 authentication mode in port vlan 1, authentication key as 123abc and
the key ID as 1: select vlan1, MD5 and key-in authentication key as 123abc and key ID as 1.