ES4710BD 10 Slots L2/L3/L4 Chassis Switch

Switch(Config-Ethernet1/10)#garp timer leave 3000

9.3.2.3garp timer hold

Command: garp timer hold <timer-value>no garp timer hold

Function: Sets the hold timer for GARP; the “no garp timer hold” command restores the default timer setting.

Parameters: < timer-value>is the value for GARP hold timer, the valid range is 100 to 327650 ms.

Command mode: Interface Mode

Default: The default value for hold timer is 100 ms.

Usage Guide: When GARP application entities receive a join message, join message will not be sent immediately. Instead, hold timer is started. After hold timer times out, all join messages received within the hold time will be sent in one GVRP frame, thus effectively reducing protocol message traffic.

Example: Setting the GARP hold timer value of port 1/10 to 500 ms. Switch(Config-Ethernet1/10)#garp timer hold 500

9.3.2.4garp timer leaveall

Command: garp timer leaveall <timer-value>no garp timer leaveall

Function: Sets the leaveall timer for GARP; the “ no garp timer leaveall” command restores the default timer setting.

Parameters: < timer-value>is the value for GARP leaveall timer, the valid range is 100 to 327650 ms.

Command mode: Global Mode

Default: The default value for leaveall timer is 10000 ms.

Usage Guide: When a GARP application entity starts, the leaveall timer is started at the same time. When leaveall timer times out, the GARP application entity will send a leaveall message. Other application entities will cancel all property information for that application entity, and the leaveall timer is cleared for a new cycle.

Example: Setting the GARP leaveall timer value to 50000 ms. Switch(Config)#garp timer leaveall 50000

9.3.2.5gvrp

Command: gvrp no gvrp

Function: Enables the GVRP function for the switch or the current Trunk port; the “no gvrp” command disables the GVRP function globally or for the port.