ES4710BD 10 Slots L2/L3/L4 Chassis Switch
a grounding post has been provided on each side of the rack for grounding connections. In addition, on both sides of the lower section of the chassis, a handler is provided for easier transport.
Fig
Management slot: 2 management slots are provided. One or two management switching modules
Network slot: 8 network slots are provided. Various network modules can be added to the network slots, such as
Power slot: used for system power supply modules. Supports up to three 600W AC modules or three 600W DC modules.
Fan tray slot: supports up to three system fan assemblies, each assembly consists of two axial fans.
Dust gauze slot: exterior air inlet for the ventilation subsystem.
Distribution box slot: for system distribution box use, works in AC/DC mode based on the power modules.
1.4.1.1Board Rack
The board rack consists of board slots and a system board.
The boards are inserted vertically into the ES4710BD 10 unit boards are provided. These include 2 management slots in the middle for management switch modules, marked specially in red as M1 and M2. The other eight board slots are network slots for various network interface modules, sequenced as 1 to 8 from left to right.
A reset button (printed on the panel as Reset), hot swap button (printed on the panel as SWAP), board power indicator (printed on the panel as PWR) and board running status indicator (printed on
37