ES4710BD 10 Slots L2/L3/L4 Chassis Switch
the port. For example, a bandwidth limit of 101 M (or more) cannot be set for a 10/100M Ethernet port. But for a 10/100/1000M port working under 100M, a bandwidth limit of 101M (or more) is permitted.
Example: setting the bandwidth limit of ports 1 – 8 of slot 3’s card to 40M. Switch(Config)#interface ethernet
7.2.1.2.2combo-forced-mode
Command:
no
Function: Sets to combo port mode (combo ports only); the “no
Parameters:
Command mode: Interface Mode
Default: The default setting for combo mode of combo ports is fiber cable port first.
Usage Guide: The combo mode of combo ports and the port connection condition determines the active port of the combo ports. A combo port consist of one fiber port and a copper cable port. It should be noted that the
For the determination of the active port in a combo port, see the table below. The headline row in the table indicates the combo mode of the combo port, while the first column indicates the connection conditions of the combo port, in which “connected” refers to a good connection of fiber cable port or copper cable port to the other devices.
| Copper | Copper | SFP forced | SFP | ||||
| forced | preferred | preferred | |||||
|
|
| ||||||
Fiber connected, copper | Copper | cable | Fiber | cable | Fiber | cable | Fiber | cable |
not connected | port |
| port |
| port |
| port |
|
Copper connected, fiber | Copper | cable | Copper | cable | Fiber | cable | Copper | cable |
not connected | port |
| port |
| port |
| port |
|
Both fiber and copper | Copper | cable | Copper | cable | Fiber | cable | Fiber | cable |
are connected | port |
| port |
| port |
| port |
|
Neither fiber nor copper | Copper | cable | Fiber | cable | Fiber | cable | Fiber | cable |
are connected | port |
| port |
| port |
| port |
|
|
|
| 160 |
|
|
|
|
|