66
EES4710BD 10 Slots L2/L3/L4 Chassis Switch
z Cleaning of power supply dust gauze:
Dust gauzes are provided in the front panels of the EM4710BD-AC and EM-7608-DC
power supply modules, which can be installed and removed easily. Dust gauze is meant to
prevent large debris or particles in the air from being ingested into the power supply
modules, and should be cleaned regularly according to operating conditions.
z Pull the dust gauze panel in lower section softly to remove the dust gauze panel and the gauze
z Clean the dust gauze. Ensure the gauze is completely dry before installation
z Install the dust gauze to its original position inside the gauze panel
z Attach the upper part of the dust gauze panel to the front panel of power module (align with
the pin holes in both sides)
z Press the dust gauze panel from the lower section softly to lock
Installation of the power supply module dust gauze is shown below:
Fig 2-6 The installation and removal of the power supply module dust gauze
2.3.4 Connecting to the console
The ES4710BD provides a RJ-45 port as the local console. Users can configure the switch through a
character terminal (usually a PC) with RS-232 ports. The connection procedures are listed below:
Step 1: Find a character terminal or a PC with a RS-232 serial port.
Step 2: Connect the RS-232 serial port of character terminal to the configuration port of the switch,
ensuring at least one of them is powered down.
Upon connection, please verify the sign above the port to avoid using the wrong port.
Notice