ES4710BD 10 Slots L2/L3/L4 Chassis Switch

219.32BogoMIPS

SST39VF040

CPU: PowerPC MPC8245MH266, Revision 14

Version: 1.4.1

Creation date: Apr 14 2005, 09:33:18

Attached TCP/IP interface to lnPci0. [Boot]:

Step 3:

Under BootROM mode, run “setconfig” to set the IP address and mask of the switch under BootROM mode, server IP address and mask, and select TFTP or FTP upgrade.

For example, suppose the switch address is 192.168.1.2/24, the PC address is 192.168.1.66/24. Select TFTP upgrade. The configuration should like:

[Boot]: setconfig

 

Host IP Address: 10.1.1.1

192.168.1.2

Server IP Address: 10.1.1.2

192.168.1.66

FTP(1) or TFTP(2): 1 2

 

Network interface configure OK. [Boot]:

Step 4:

Enable FTP/TFTP server in the PC. For TFTP, run TFTP server program; for FTP, run FTP server program. Before downloading the upgrade file to the switch, verify the connectivity between the server and the switch by ping from the server. If ping succeeds, run “load” command in the BootROM mode from the switch; if it fails, perform troubleshooting to find out the cause. The following is the configuration for the system update mirror file.

[Boot]: load nos.img Loading...

entry = 0x10010 size = 0x1077f8

Step 5:

Example: Execute “write nos.img” in BootROM mode. The following saves the system update

122

Page 123
Image 123
Accton Technology ES4710BD manual 192.168.1.66