122
EES4710BD 10 Slots L2/L3/L4 Chassis Switch
219.32 BogoMIPS
SST39VF040
CPU: PowerPC MPC8245MH266, Revision 14
Version: 1.4.1
Creation date: Apr 14 2005, 09:33:18
Attached TCP/IP interface to lnPci0.
[Boot]:
Step 3:
Under BootROM mode, run “setconfig” to set the IP address and mask of the switch under
BootROM mode, server IP address and mask, and select TFTP or FTP upgrade.
For example, suppose the switch address is 192.168.1.2/24, the PC address is 192.168.1.66/24.
Select TFTP upgrade. The configuration should like:
[Boot]: setconfig
Host IP Address: 10.1.1.1 192.168.1.2
Server IP Address: 10.1.1.2 192.168.1.66
FTP(1) or TFTP(2): 1 2
Network interface configure OK.
[Boot]:
Step 4:
Enable FTP/TFTP server in the PC. For TFTP, run TFTP server program; for FTP, run FTP server
program. Before downloading the upgrade file to the switch, verify the connectivity between the
server and the switch by ping from the server. If ping succeeds, run “load” command in the
BootROM mode from the switch; if it fails, perform troubleshooting to find out the cause. The
following is the configuration for the system update mirror file.
[Boot]: load nos.img
Loading...
entry = 0x10010
size = 0x1077f8
Step 5:
Example: Execute “write nos.img” in BootROM mode. The following saves the system update