151
EES4710BD 10 Slots L2/L3/L4 Chassis Switch

Chapter 6 Device Management

6.1 Device Management Brief
The device management function of ES4710BD provides information about line card status,
line card operation debugging, power supply and fan status. This function enables the maintenance
and management of the physical devices and restart of the switch and line cards, and hot swapping
of the cards. ES4710BD supports dual-master mode. If 2 master control boards are present in the
system, the master control board in the smaller slot number becomes the Active Master and the other
board becomes the Standby Master.
6.2 Device Management Configuration
5.6.1 SWITCH BASIC CONFIGURATION
Command: reset slot <slotno>
Function: Resets specified card.
Parameters: < slotno> is the slot number, or the card located in that slot, the valid range is 1 to 4,
M1, M2, and 5 to 8.
Command mode: Admin Mode
Usage Guide: This command can reset all line cards and Standby Master board, but not the Active
Master board.

6.2.2 Device Management Troubleshooting Help

6.2.2.1 Monitor and Debug Commands

6.2.2.1.1 show slot

Command: shows slot [<slotno>]
Function: Shows basic information of the specified card.
Parameters: < slotno> is the slot number, or the card located in that slot, the valid range is 1 to 4,
M1, M2, and 5 to 8.
Default: If no slotno is specified, information for all cards is listed by default.
Command mode: Admin Mode