91
EES4710BD 10 Slots L2/L3/L4 Chassis Switch
Unrecognized command or illegal
parameter!
The entered command does not exist, or there is error
in parameter scope, type or format.
Ambiguous command At least two interpretation are possible based on the
current input.
Invalid command or parameter The command is recognized, but no valid parameter
record is found.
This command does not exist in current
mode
The command is recognized, but this command can
not be used under current mode.
Please configure precursor command
"*" at first!
The command is recognized, but the prerequisite
command has not been configured.
Syntax error: missing '"' before the end
of command line!
Quotation marks are not used in pairs.
4.2.1.6 Fuzzy match support
ES4710BD Shell support fuzzy match in searching for commands and keywords. Shell will
recognize commands or keywords correctly if the entered string causes no conflict.
For example:
1. For Admin configuration command “show interface ethernet 1/1”, simply typing in
“sh in e 1/1” will work.
2. However, for Admin configuration command “show running-config”, the system will,
if only “show r” is entered, report a “> Ambiguous command!” error. Shell is unable
to tell whether it is “show rom” or “show running-config”. Therefore, Shell will only
recognize the command if the minimum of “sh ru” is entered.
4.3 Web Management 4.3.1 Main Page
ES4710BD routing switch provides HTTP web management function and users can configure
and monitor the status of the switch through the web interface.
To manage the switch through web browser use the following steps:
Configure valid IP address, mask and confirm gateway for the switch. Please reference to 5.3
1. Configure web user management and its password
2. Connect to the switch using the web browser. Enter the username and password to
proceed to web management.