34. Gain Compression, HP 8591EM
23.On the EMC analyzer, press 4SGL SWP5, then wait for the completion of a new sweep. Press 4MKR !5 MKR ! HIGH More 1 of 3 More 2 of 3 MARKER 1 .
24.On the synthesized sweeper, set RF to ON.
25.On the EMC analyzer, press 4SGL SWP5, then wait for the completion of a new sweep. Press 4MKR !5 MKR ! HIGH More 1 of 3 More 2 of 3 MARKER 1 .
26.Read the MKR 1 amplitude and record in the performance verication test record as TR Entry 2.