60. Tracking Generator Feedthrough, HP 8593EM, HP 8595EM, and HP 8596EM Option 010
11.Press 4FREQUENCY5 and adjust the center frequency until the LO feedthrough peak is on the
4SPAN5 50 4kHz5
4AMPLITUDE5 REF LVL 57 4dBV5
4BW5 IF BW AUTO MAN (MAN) 1 4kHz5 AVG BW AUTO MAN (MAN) 30 4Hz5
4TRACE5 More 1 of 4 More 2 of 4 DETECTOR SMP PK (SMP)
12.Press 4AUX/USER5, Track Gen , SRC PWR ON OFF (ON), then enter 106
4dBV5.
13.Press 4SGL SWP5 , then wait for completion of a new sweep. Press 4DISPLAY5,
DSP LINE ON OFF (ON).
14.Adjust the display line so that it is centered on the average trace noise, ignoring any residual responses. Record the display line amplitude setting in Table
15.Repeat steps 13 and 14 for the remaining Tracking Generator Output Frequencies (EMC analyzer center frequency) listed in Table
16.In Table
Performance Verication Tests