47. Fast Time Domain Sweeps, HP 8591EM Option 101 and Option 301
Procedure
Fast Sweep Time Amplitude A ccuracy
1.Connect the equipment as shown in Figure
2.On the EMC analyzer, press 4PRESET5, then wait for the preset routine to nish. Set the EMC analyzer by pressing the following keys:
4FREQUENCY5 300 4MHz5
4SPAN5 0 4Hz5
4SWEEP/TRIG5 20 4ms5
4AMPLITUDE5 SCALE LOG/LIN (LIN) REF LVL 25 4mV5
4MKR5 More 1 of 3 More 2 of 3 MK NOISE ON OFF (ON)
4SGL SWP5
4MKR5 MARKER 1
3.Set the sweep time to 18 ms. Press 4SGL SWP5 and read the MKR 1 amplitude. Record the
Fast Sweep Time Accuracy
4. Connect the equipment as shown in Figure
Figure
5.Set the signal generator to output a 300 MHz, 04 dBm, CW signal. Set the AM and FM controls to OFF.
6.Set the synthesizer/level generator to output a 556 Hz, +5 dBm, signal.
Performance Verication Tests