48.Fast Time Domain Sweeps, HP 8593EM, HP 8594EM, HP 8595EM, and HP 8596EM Option 101 and Option 301
4MKR !5 MKR ! HIGH
If necessary, press NEXT PEAK or NEXT PK LEFT until the marker is on the
11.Press More 1 of 3 More 2 of 3 MARKER 1 , MARKER 1 , then press
NEXT PK RIGHT until the marker 1 is on the eighth signal.
12.Record the MKR 1 frequency reading in the performance verication test record as shown in Table
13.Repeat steps 10 through 12 for the remaining sweep time settings listed in Table
Table
EMC Analyzer | Synthesizer/Function | Minimum | TR Entry | ||
Sweep Time | Generator Frequency | Reading | (MKR 1) | ||
|
|
|
|
| |
18 ms | 556 Hz | 14.04 | ms | 1 | |
10 ms | 1 kHz | 7.8 | ms | 2 | |
1.0 ms | 10 kHz | 780 | s | 3 | |
100 s | 100 | kHz | 78 s | 4 | |
20 s | 500 | kHz | 15.6 | s | 5 |
|
|
|
|
|
|
Performance Verication Tests