Agilent Technologies E6380-90073 manual PNMode string PNMode?, PNOFfset real number PNOFfset?

Models: E6380-90073

1 352
Download 352 pages 53.27 Kb
Page 108
Image 108

GPIB Command Dictionary

CANalyzer subsystem

:PNMode <string> :PNMode?

These commands set/query the PN offset mode.

‘Auto’ is used to calculate the system’s PN offset if it is unknown. When ‘Auto’ is selected, the CAN:PNIN command can be used to enter a PN increment and speed the PN offset calculation.

‘Manual’ is used to enter a known PN offset. When ‘Manual’ is selected, the PN offset is entered using the CAN:PNOF command.

Syntax

CAN:PNM ‘Auto’

‘Manual’

CAN:PNM? !returns the PN Offset mode

Screen/field equivalent

CAN:PNM controls the Find PN field on the CDMA ANALYZER screen.

:PNOFfset <real number> :PNOFfset?

These commands set/query the PN offset of the system.

This command utilizes the :INCR command of the “Real Number

Setting Syntax” on page 299.

Syntax

CAN:PNOF <real number> !values from 0.0 to 511.984375

CAN:PNOF?

!returns the value of the PN Offset

Screen/field equivalent

CAN:PNOF controls the PN Offset field on the CDMA ANALYZER screen. This field is displayed only when the Find PN field is set to Manual.

108

Chapter 1

Page 108
Image 108
Agilent Technologies E6380-90073 manual PNMode string PNMode?, PNOFfset real number PNOFfset?