GPIB Command Dictionary
CANalyzer subsystem
:PNMode <string> :PNMode?
These commands set/query the PN offset mode.
•‘Auto’ is used to calculate the system’s PN offset if it is unknown. When ‘Auto’ is selected, the CAN:PNIN command can be used to enter a PN increment and speed the PN offset calculation.
•‘Manual’ is used to enter a known PN offset. When ‘Manual’ is selected, the PN offset is entered using the CAN:PNOF command.
Syntax
CAN:PNM ‘Auto’
‘Manual’
CAN:PNM? !returns the PN Offset mode
Screen/field equivalent
CAN:PNM controls the Find PN field on the CDMA ANALYZER screen.
:PNOFfset <real number> :PNOFfset?
These commands set/query the PN offset of the system.
This command utilizes the :INCR command of the “Real Number
Setting Syntax” on page 299.
Syntax
CAN:PNOF <real number> !values from 0.0 to 511.984375
CAN:PNOF? | !returns the value of the PN Offset |
Screen/field equivalent
CAN:PNOF controls the PN Offset field on the CDMA ANALYZER screen. This field is displayed only when the Find PN field is set to Manual.
108 | Chapter 1 |