GPIB Command Dictionary

AFG1AFGENERATOR1 subsystem

AFG1AFGENERATOR1 subsystem

:AM <real number> :AM?

This command sets AM modulation depth when the AFG1:DEST ‘AM’ is used first.

This command utilizes the “Real Number Setting Syntax” on page 299.

Syntax

AFG1:AM <real number>

AFG1:AM? !returns the value of the amplitude modulation

Screen/field equivalent

AFG1:AM controls the AFGen1 To field (lower subfield) on the RF

GENERATOR screen.

:DESTination <string> :DESTination?

AFG1:DEST sets/queries the destination of AF generator 1’s signal.

Syntax

AFG1:DEST ‘AM’

‘FM’

‘Audio Out’

AFG1:DEST?

Screen/field equivalent

AFG1:DEST controls the AFGen1 To field (upper subfield) on the RF GENERATOR screen.