GPIB Command Dictionary

AFG2ENCoder subsystem

:POLarity <string> :POLarity?

This command causes the digitally modulated signals to be sent with a normal or inverted response to the digital data. When Inverted, a digital 1 produces a frequency shift in an FM carrier opposite to normal operation.

Syntax

AFG2:POL ‘Norm’

‘Invert’

AFG2:POL?

Screen/field equivalent

AFG2:POL controls the Polarity field on the SIGNALING ENCODER screen when the Mode field is set to AMPS-TACSor NAMP-NTAC.

:SEND:MODE <string> :SEND:MODE?

These commands set/query the mode used when a message is sent.

‘Single’ outputs the entire message once.

‘Burst’ outputs the message the number of times specified by the AFG2:BURS command.

‘Cont’ outputs the message continuously until the AFG2:STOP command is sent.

‘Step’ outputs a single step in an encoder sequence each time the AFG2:SEND command is sent. After the entire sequence is output, the encoder returns to the first character in the sequence.

Syntax

AFG2:SEND:MODE ‘Single’

‘Burst’

‘Cont’

‘Step’

AFG2:SEND:MODE?

Screen/field equivalent

AFG2:SEND:MODE controls then Send Mode field on the SIGNALING ENCODER screen when the Mode field is set to AMPS-TACS, NAMP-NTAC, or DTMF.