GPIB Command Dictionary

CANalyzer subsystem

:POWer:GAIN:MODE <string> :POWer:GAIN:MODE?

These commands set/query the mode of the Pwr Gain field, allowing you to choose between automatic gain (Auto) or fixed gain (Hold).This command is valid only when average power is selected. For channel power, EVM and rho measurements, use the CAN:PATH:GAIN:MODE command.

Syntax

CAN:POW:GAIN:MODE ‘Auto’

‘Hold’

CAN:POW:GAIN:MODE?

Screen/field equivalent

CAN:POW:GAIN:MODE sets the Auto/Hold subfield of the Pwr Gain field of the CDMA ANALYZER screen, when Avg Pwr is displayed.

:POWer:SAMPle:TIME <real number> :POWer:SAMPle:TIME?

These commands set/query the power interval. This interval is the amount of time that average power or channel power is measured.This command utilizes the “Real Number Setting Syntax” on page 299, but does not use the :STATe command.

Syntax

CAN:POW:SAMP:TIME <real number>

!values from 0.00025 to .02666 s

CAN:POW:SAMP:TIME?

Screen/field equivalent

CAN:POW:SAMP:TIME sets the Pwr Intvl field of the CDMA

ANALYZER screen.

110

Chapter 1

Page 110
Image 110