GPIB Command Dictionary

AFANalyzer subsystem

:DEMPhasis:GAIN <string> :DEMPhasis:GAIN?

These commands set/query the AF analyzer’s amplifier gain. This command is only effective when autoranging is turned off using the AFAN:RANG ‘Hold’ command.

Gain is automatically set when the AFAN:RANG ‘Auto’ command is used. If autoranging is enabled (AFAN:RANG ‘Auto’) and you attempt to change the gain setting by sending the AFAN:DEMP:GAIN command, the value you send will be overridden by the autoranging function.

Syntax

AFAN:DEMP:GAIN ‘0 dB’

‘10 dB’

‘20 dB’

‘30 dB’

AFAN:DEMP:GAIN?

Screen/field equivalent

AFAN:DEMP:GAIN sets the De-Emp Gain field on the AF ANALYZER screen when the Gain Cntl field is set to Hold.

Chapter 1

55

Page 55
Image 55
Agilent Technologies E6380-90073 manual DEMPhasisGAIN string DEMPhasisGAIN?