GPIB Command Dictionary
CDANalyzer subsystem
:IS2000:GAIN:MODE <string> :IS2000:GAIN:MODE?
For
This command may conflict with the CDMA analyzer’s settings CAN:PATH:GAIN and CAN:PATH:MODE. For example, if autoranging is turned off (‘Hold’) in the CDMA analyzer and turned on in the Code Domain Analyzer (‘Auto’), the ‘Hold’ setting will always override the ‘Auto’ setting. When autoranging is turned off, setting either analyzer’s path gain will automatically change the other’s to the same setting.
For average power measurements, use the CAN:POW:GAIN:MODE command.
Syntax
CDAN:IS2000:GAIN:MODE ‘Auto’
‘Hold’
CDAN:IS2000:GAIN:MODE?
Screen/field equivalent
CDAN:IS2000:GAIN:MODE sets the Auto/Hold subfield of the Gain image of the CODE DOMAIN screen when the CDMA standard is set to
:IS2000:GAIN:PATH <real number> :IS2000:GAIN:PATH?
For
Syntax
CDAN:IS2000:GAIN:PATH <real number> !values from 0 to 36 dB in 0.1 dB steps
CDAN:IS2000:GAIN:PATH?
Screen/field equivalent
CDAN:IS2000:GAIN:PATH has no corresponding field. This applies when the CDMA standard is set to
132 | Chapter 1 |