GPIB Command Dictionary
MEASure subsystem
:CANalyzer:POWer:ACP:URATio <meas cmnd> :CANalyzer:POWer:ACP:URATio?
These commands set/query upper ratio measurement of the adjacent channel power measurement. This ratio is the ratio of the total power in the specified bandwidth at the specified offset above the center frequency, to the power at the center frequency.
Syntax
MEAS:CAN:POW:ACP:URAT <meas cmd>
!See “Number Measurement Syntax” on page 283. MEAS:CAN:POW:ACP:URAT?
Screen/field equivalent
MEAS:CAN:POW:ACP:URAT? reads the Upper ACP Ratio measurement field on the CDMA ANALYZER screen when an ACP measurement is selected. This measurement is also displayed on the CDMA GENERATOR screen.
:CANalyzer:POWer:ACP:CENTer <meas cmnd> :CANalyzer:POWer:ACP:CENTer?
These commands set/query center channel measurement of the adjacent channel power measurement.
Syntax
MEAS:CAN:POW:ACP:CENT <meas cmd>
!See “Number Measurement Syntax” on page 283. MEAS:CAN:POW:ACP:CENT?
Screen/field equivalent
MEAS:CAN:POW:ACP:CENT? reads the Center Channel measurement field on the CDMA ANALYZER screen when an ACP measurement is selected. This measurement is also displayed on the CDMA GENERATOR screen.
Chapter 1 | 223 |